Heaveguard

Heaveguard is a compressible low density Expanded Polystyrene product, used when foundations need to be protected against ground heave. As an integral part of the Cordek solution to ground heave, Heaveguard is used to protect against lateral heave, typically on the inside face of piled ground beams or deep trench fill foundations.

Features

  • Reduces the lateral force transmitted to the structure
  • BBA certified
  • Meets the NHBC’s Technical Standards
  • Wide range of sheets sizes and thicknesses to suit most applications
  • Available as a pile collar to aid installation of Cordek’s Cellcore range
  • Coloured green for easy identification on site

Applications

Heaveguard is used to protect against lateral heave, typically on the inside face of piled ground beams or deep trench fill foundations.

Suitability

The required thickness of Heaveguard is based upon the predicted lateral movement and recommended void guidance provided by the NHBC, as detailed in table one below. Note: Heaveguard and all other compressible polystyrenes do not compress significantly until loads exceed 20 kN/m2. A load of 40 kN/m2 is needed to produce 50% compression of the product. For this reason Heaveguard is not recommended for use under ground floor slabs, piled beams or pile caps.

Table One:

Results of Soil AnalysisShrinkage PotentialPredicted lateral movement NHBC recommended voidHeaveguard thickness for 'Equivalent Void'
10-20LowZeroZero
20-40Medium25mm50mm
40-60*High*35mm75mm


*When the analysis exceeds 60 or the shrinkage potential is greater than High, please consult the Cordek Technical Team on 01403 799600 for further information.

User Notice

To view our technical documents, we recommend using alternative internet browsers to Chrome (such as Microsoft Edge, Internet Explorer, or Firefox) whilst Google rectify their Chrome browser and PDF document compatibility issue. We apologise for any inconvenience caused.

Downloads

Data Sheets

Product Issue Date Version Size Download
Heaveguard Data Sheet 06/2017 1 1.7 MB

MSDS Data Sheets

Product Issue Date Version Size Download
Expanded Polystyrene MSDS 06/2017 5 137.3 KB

Brochures

Product Issue Date Version Size Download
Construction Solutions 01/2020 2 6.6 MB
Ground Heave Solutions 08/2017 1 1,014.7 KB

Installation Guides

Product Issue Date Version Size Download
Heaveguard Installation Guide 12/2018 1 363.2 KB

NBS Clauses

Our NBS Clauses are hosted on the external website - view NBS Clauses

BIM Library

Please select the BIM file in the format you require.

Name IFC Size IFC Download Revit Size Revit Download
Sorry, no matching files

Not sure which product meets your requirements?

Contact a Technical Advisor now

Find your nearest Technical Advisor

For international enquiries please contact Peter Blanchard

For enquiries in the Manchester or Liverpool
areas please contact James Provan

Or contact Cordek Head Office

Cordek